Varicella Zoster Virus (VZV) Antibody, IgM, Serum
VZV
    Test Codes
    EPIC: LAB163, Beaker: XVZM, Warde: VARM
    Department
    Send Outs
    Instructions
    Acute and convalescent specimens must be labeled as such; parallel testing is preferred, and convalescent specimens MUST be received within 30 days of the acute specimens. Please mark specimen plainly as "acute" or "convalescent."
    Specimen Collection Criteria
    Collect (preferred specimen): One Gold-top SST tube.
Also acceptable: One plain Red-top tube.
    Physician Office/Draw Specimen Preparation
    Let specimen clot 30-60 minutes then centrifuge to separate serum from cells within two hours of collection. Transfer serum to a plastic transport tube and freeze (-20°C/-4°F or below).
    Preparation for Courier Transport
    Transport: 1.0 mL serum, frozen (-20°C/-4°F or below). (Minimum: 0.5 mL)
    Rejection Criteria
    
    - Hemolyzed specimens. 
- Severely lipemic specimens.
- Specimens not collected and processed as indicated.
In-Lab Processing
    Let specimen clot 30-60 minutes then centrifuge to separate serum from cells within two hours of collection. Transfer serum to a plastic transport tube and freeze (-20°C/-4°F or below).
Transport: 1.0 mL serum, freeze (-20°C/-4°F or below). (Minimum: 0.5 mL)
    Storage
    Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 8 hours
Refrigerated (2-8°C or 36-46°F): 48 hours
Frozen (-20°C/-4°F or below): 14 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
    Laboratory
    Sent to Warde Medical Laboratory, Ann Arbor, MI.
    Performed
    Sunday, Tuesday, Thursday.
Results available in 2-5 days.
    Reference Range
    Negative: Less than or equal to 0.90 Index - No significant level of detectable varicella-zoster virus IgM antibody.
Equivocal: 0.91-1.09 Index - Repeat testing in 10-14 days may be helpful.
Positive: Greater than or equal to 1.10 Index - Significant level of detectable varicella-zoster virus IgM antibody. Indicative of current or recent infection.
    Test Methodology
    Enzyme-Linked Immunosorbent Assay (ELISA).
    CPT Codes
    86787