Zinc, RBC
Test Codes
EPIC: LAB1231342, Beaker: XZNCR, Warde: ZNRBC
Department
Send Outs
Specimen Collection Criteria
Collect: One Royal Blue-top EDTA tube.
Also acceptable: One lavender-EDTA tube.
Physician Office/Draw Specimen Preparation
Centrifuge to separate red blood cells from plasma. Transfer red blood cells to a metal free plastic transport tube and refrigerate (2-8°C or 36-46°F). Discard the plasma. Please label “Packed RBC’s.”
If plastic metal free tubes are not available- Centrifuge, remove plasma and send original dark blue EDTA tube with just RBCs. Write on label “RBC’s”.
Preparation for Courier Transport
Transport: 0.5 mL red blood cells, refrigerated (2-8°C or 36-46°F). (Minimum: 0.3 mL)
Rejection Criteria
- Frozen specimen.
- Clotted specimen.
- Hemolyzed specimen
- Specimens not collected and processed as indicated.
In-Lab Processing
Centrifuge to separate red blood cells from plasma. Transfer red blood cells to a metal free plastic transport tube and refrigerate (2-8°C or 36-46°F). Discard the plasma. Please label “Packed RBCs”.
If plastic metal free tubes are not available- Centrifuge, remove plasma and send original dark blue EDTA tube with just RBCs. Write on label “RBC’s”.
Transport: 0.5 mL red blood cells, refrigerated (2-8°C or 36-46°F). (Minimum: 0.3 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 7 days
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Warde Medical Laboratory, Ann Arbor, MI. Forwarded to Quest Diagnostics Nichols Institute of Valencia, Valencia, CA.
Performed
Tuesday – Saturday.
Results available in 5-7 days.
Reference Range
9 –14.7 mg/L.
Test Methodology
Inductively Coupled Plasma / Mass Spectrometry.
CPT Codes
84630
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
7/21/2024