Trimipramine Level (including Nortrimipramine)
Surmontil, Trimipramine Level
Test Codes
Antrim #31514, EPIC: LAB1231003, SOFT: TRIMP
Department
Toxicology
Specimen Collection Criteria
Collect: One plain Red-top tube. (Minimum Whole Blood: 2.0 mL)
Do not use Serum Separator Tubes.
Time of Collection: Trough, just prior to the next dose.
Record the exact time of specimen collection on the tube or in the computer system.
Physician Office/Draw Specimen Preparation
Let specimens clot 30-60 minutes. Centrifuge specimen to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection. (Minimum: 0.5 mL serum)
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL serum)
Rejection Criteria
- Serum Separator (SST) tubes.
- Severely lipemic or hemolyzed specimens.
In-Lab Processing
Let specimens clot 30-60 minutes. Centrifuge specimen to separate serum from cells. Deliver immediately to the appropriate testing station.
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 24 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 3 months
Specimen Storage in Department Prior to Disposal:
Frozen (-20°C/-4°F or below): 2 months
Laboratory
Royal Oak Toxicology Laboratory
Performed
Monday, Thursday.
Results available the same day as testing performed (1-4 days).
Reference Range
Therapeutic range (parent + metabolite): 100-300 ng/mL.
Critical: Greater than 500 ng/mL.
Test Methodology
Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS).
This test was developed and its performance characteristics determined by Beaumont Health. It has not been cleared or approved by the FDA. The Laboratory is regulated under CLIA as qualified to perform high-complexity testing. This test is used for clinical purposes and should not be regarded as investigational or for research.
Interpretation
Trimipramine metabolism varies within the population and there is a poor correlation between dose and steady-state serum concentration.
Clinical Utility
This assay is used to monitor the therapeutic drug level and evaluate the toxicity of trimipramine. Trimipramine is a tricyclic antidepressant used in the treatment of depression.
CPT Codes
80335 (alternate: G0480).
LOINC: 25812-9, Trimipramine 4083-2, 4084-0, Notrimipramine 16746-0, 58015-9
Contacts
Toxicology Laboratory – RO
248-551-8058
Name: Toxicology Laboratory – RO
Location:
Phone: 248-551-8058
Last Updated
7/21/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.