Tree Nut Panel (IgE)
Tree Nut Allergy Panel, Tree Nut Panel
Test Codes
EPIC: LAB1231160, SOFT: ETREE
Department
Immunology
Instructions
This panel includes: Almond, Brazil Nut, Cashew, Coconut, Hazelnut, Macadamia, Pecan, Pine Nut, Pistachio Nut, Peanut, Sweet Chestnut, and Walnut.
Specimen Collection Criteria
Collect: One Gold-top SST tube.
Twenty individual allergen assays or allergen screens can be performed on one 5 mL Gold-top SST tube. Each allergen assay requires 100 mcL of serum.
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection.
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F).
Rejection Criteria
Plasma specimens.
Severely lipemic or hemolyzed specimens.
In-Lab Processing
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours.
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-25°C or 68-77°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 1 month
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Royal Oak Special Testing Laboratory
Performed
Monday – Friday.
Results available the next business day.
Reference Range
Allergy Reference Range: Less than 0.35 kU/L.
Range (kU/L) |
Class |
Interpretation |
≤ 0.34 |
0 |
Negative |
0.35-0.69 |
1 |
Low |
0.70-3.49 |
2 |
Medium |
3.50-17.49 |
3 |
High |
17.50-49.99 |
4 |
Very High |
50.0-100.0 |
5 |
Very High |
> 100 |
6 |
Very High |
Test Methodology
Fluorescence Enzyme Immunoassay (FEIA).
Interpretation
The allergen class may not be predictive of clinical disease in some patients. The diagnosis of allergy should be based upon patient history and clinical findings. The diagnosis of allergy should not be based upon laboratory findings alone.
Clinical Utility
Positive assay results indicate a high probability of allergic disease. Negative assay results effectively rule out allergy induced by those allergens.
CPT Codes
86003x12.
Contacts
Special Chemistry Laboratory – RO
248-551-8071
Name: Special Chemistry Laboratory – RO
Location:
Phone: 248-551-8071
Last Updated
10/16/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.