Thyroid Stimulating Hormone (TSH), 3rd Generation
Thyrotropin
Test Codes
EPIC: LAB1231632, Beaker: TSHG, Cord Blood: EPIC: LAB6598, Beaker: TSHCB, Antrim: 16970
Department
Toxicology
Specimen Collection Criteria
Collect: One Gold-top SST tube (adults) or one full Gold-top Microtainer® (pediatric). (Minimum Whole Blood: 4.0 mL)
Contact the Laboratory for the acceptability of other tube types.
See Minimum Pediatric Specimen Requirements for Microtainer® collection.
Physician Office/Draw Specimen Preparation
Let SST specimens clot for 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged SST tube within two hours of collection. (Minimum: 1.0 mL)
Preparation for Courier Transport
Transport: Centrifuged SST tube, refrigerated (2-8°C or 36-46°F). (Minimum: 1.0 mL)
Rejection Criteria
- Grossly hemolyzed specimens.
- Red-top tubes with serum not separated from cells within two hours of collection.
In-Lab Processing
Let SST specimens clot 30-60 minutes. Centrifuge SST tubes or Microtainers® to separate serum from cells. Deliver immediately to the appropriate testing station.
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Dearborn Chemistry Laboratory
Farmington Hills Chemistry Laboratory
Grosse Pointe Chemistry Laboratory
Royal Oak Automated Chemistry Laboratory
Taylor Chemistry Laboratory
Trenton Chemistry Laboratory
Troy Chemistry Laboratory
Wayne Chemistry Laboratory
Performed
Sunday – Saturday, 24 hours a day.
Results available within 24 hours of receipt in the Chemistry Laboratory.
Reference Range
TSH (3rd Generation)
Cord Blood: | 1.00 – 39.00 mcIU/mL. |
1 Year – Adult | 0.40 – 4.50 mcIU/mL. |
Pediatric Ranges:
|
0 - 2 Days: | 3.20 – 34.60 mcIU/mL. |
3 - 4 Days | 0.70 – 15.40 mcIU.mL. |
5 Days – < 1 Months | 1.70 – 9.10 mcIU/mL. |
1 Month – < 1 Year | 0.80 – 8.20 mcIU/mL. |
TSH (3rd Generation) Pregnancy
1st Trimester: | 0.26 - 2.66 mcIU/mL |
2nd Trimester: | 0.55 - 2.73 mcIU/mL. |
3rd Trimester: | 0.43 - 2.91 mcIU/mL. |
Test Methodology
Chemiluminescent Immunoassay.
Interpretation
Hypothyroidism: |
Elevated TSH substantiated by clinical correlation |
Hyperthyroidism: |
Depressed TSH substantiated by clinical correlation |
Heterophilic antibodies in human serum can react with reagent immunoglobulins, interfering with in vitro immunoassays. Patients routinely exposed to animals or animal serum products can be prone to this interference and anomalous high values can be observed. Additional information may be required for diagnosis.
TSH levels during the first trimester of pregnancy, or whenever very high levels of hCG are present, should be interpreted with caution.
Clinical Utility
TSH levels aid in evaluating thyroid function and replacement therapy. They are especially useful in the differential diagnosis of primary (thyroid) from secondary (pituitary) and tertiary (hypothalamus) hypothyroidism. In primary hypothyroidism, TSH levels are significantly elevated, while in secondary and tertiary hypothyroidism, TSH levels are low or normal.
When testing patients on thyroid hormone replacement, blood should be obtained shortly before the patients next dose. Testing shortly after thyroid hormone intake should not affect TSH results, however it may result in an apparently elevated free T4. If a patient's dose of thyroid hormone is changed, it is recommended that 6-8 weeks be allowed to elapse before retesting.
CPT Codes
84443
Contacts
Chemistry Laboratory – DBN
313-436-2196
Name: Chemistry Laboratory – DBN
Location:
Phone: 313-436-2196
Chemistry Laboratory – FH
947-521-5252
Name: Chemistry Laboratory – FH
Location:
Phone: 947-521-5252
Chemistry Laboratory – GP
313-473-1807
Name: Chemistry Laboratory – GP
Location:
Phone: 313-473-1807
Automated Chemistry Laboratory – RO
248-551-8065
Name: Automated Chemistry Laboratory – RO
Location:
Phone: 248-551-8065
Chemistry Laboratory – TYL
313-295-5360
Name: Chemistry Laboratory – TYL
Location:
Phone: 313-295-5360
Chemistry Laboratory – TRN
734-671-3165
Name: Chemistry Laboratory – TRN
Location:
Phone: 734-671-3165
Chemistry Laboratory – TR
248-964-8070
Name: Chemistry Laboratory – TR
Location:
Phone: 248-964-8070
Main Laboratory –WYN
734-467-4274
Name: Main Laboratory –WYN
Location:
Phone: 734-467-4274
Last Updated
7/21/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.