Thyroid Autoantibody Panel (Southeast Michigan Only)
Includes: Thyroid Peroxidase Autoantibody (Anti-Microsomal Antibody, Anti-TPO, Anti-Thyroid Peroxidase, Thyroid Peroxidase Antibody, TPO) and Anti Thyroglobulin Antibody (Anti-Thyroglobulin, ATG, Anti-Tg, Thyroglobulin Antibody).
Test Codes
EPIC: LAB1231476, SOFT: THYPN
Department
Immunology
Specimen Collection Criteria
Collect: One Gold-top SST tube. (Minimum Whole Blood: 2.0 mL)
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuge collection tube within two hours of collection. (Minimum Serum: 0.5 mL)
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F). (Minimum Serum: 0.5 mL)
Rejection Criteria
- Plasma specimens.
- Severely lipemic, icteric, or grossly hemolyzed specimens.
In-Lab Processing
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours. (Minimum Serum: 0.5 mL)
Storage
Specimen Stability for Testing:
Centrifuged SST tubes, Red-top tubes, and Microtainers®
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Indefinitely
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Royal Oak Special Testing Laboratory
Performed
Monday – Friday.
Results available in two business days.
Reference Range
See individual tests for reference ranges.
This panel includes: Thyroid Peroxidase Autoantibody and Anti Thyroglobulin Antibody.
Test Methodology
Chemiluminescent Immunoassay.
Interpretation
See individual tests for interpretation.
This panel includes: Thyroid Peroxidase Autoantibody and Anti Thyroglobulin Antibody.
Clinical Utility
The Anti Thyroglobulin Antibody and Thyroid Peroxidase Autoantibody assays are used to aid in the diagnosis of autoimmune thyroid disease.
CPT Codes
86376, 86800, 8098-6
Contacts
Special Chemistry Laboratory – RO
248-551-8071
Name: Special Chemistry Laboratory – RO
Location:
Phone: 248-551-8071
Last Updated
11/22/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.