Thioridazine/Mesoridazine
Mellaril®
Test Codes
NMS: 4461SP, Order as a Miscellaneous Send Out.
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One plain Red-top tube.
Also acceptable: One Lavender-top EDTA tube.
Do not use Serum Separator Tubes.
Time of Collection: Trough, just prior to the next dose.
Physician Office/Draw Specimen Preparation
Centrifuge to separate serum or plasma from cells. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 2.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.7 mL)
Rejection Criteria
- Serum Separator (SST) tubes.
- Specimens not collected and processed as indicated.
In-Lab Processing
Centrifuge to separate serum or plasma from cells. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Transport: 2.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.7 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 8 days
Refrigerated (2-8°C or 36-46°F): 8 days
Frozen (-20°C/-4°F or below): 12 months
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to ARUP Laboratories, Salt Lake City, UT, forwarded to National Medical Services (NMS), Willow Grove, PA.
Performed
Tuesday, Thursday.
Results available in 4-10 days.
Reference Range
By report.
Test Methodology
Gas Chromatography.
Interpretation
Chronic high therapeutic concentrations for total drug may reach 7 mcg/mL. Toxic range is not well defined. Some patients may show toxicity at therapeutic concentrations.
Clinical Utility
Thioridazine is indicated for the management of manifestations of psychotic disorders. This assay is used to monitor the therapeutic drug level and to evaluate toxicity of thioridazine.
CPT Codes
80342
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
10/3/2023
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.