Smith Antibody
Sm Antibody, Anti-Smith, Anti-Sm
Test Codes
EPIC: LAB858, Beaker: SMTHA
Department
Immunology
Specimen Collection Criteria
Collect: One Gold-top SST tube. (Minimum Whole Blood: 2.0 mL)
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection. (Minimum Serum: 0.5 mL)
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated (2-8 °C or 36-46 °F). (Minimum Serum: 0.5 mL)
Rejection Criteria
- Plasma specimens.
- Severely hemolyzed, lipemic or icteric specimens.
In-Lab Processing
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours. (Minimum Serum: 0.5 mL)
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gels
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gels
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 2 months
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Royal Oak Special Testing Laboratory
Performed
Monday – Friday.
Results available within 2 business days.
Reference Range
Positive, Negative.
Test Methodology
Multiplex Flow Assay.
Interpretation
A positive result for Smith antibody is consistent with a diagnosis of lupus erythematosus.
Clinical Utility
Smith antibodies are detected in approximately 30% of patients with lupus erythematosus. The levels of Smith antibodies remain relatively constant over time in lupus patients and are commonly found in individuals that also have RNP antibodies. Testing for Smith antibodies is not useful in patients negative for antinuclear antibodies.
CPT Codes
86235
LOINC: 21523-6
Contacts
Special Chemistry Laboratory – RO
248-551-8071
Name: Special Chemistry Laboratory – RO
Location:
Phone: 248-551-8071
Last Updated
11/20/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.