Premature Adrenarche: Profile 2
Test Codes
EPIC: LAB1231616, Beaker: XPA2, MAYO: (custom panel)
Department
Send Outs
Instructions
This profile includes: Androstenedione, DHEA, Testosterone, 17-OH-Pregnenolone, and 17-A-OH-Progesterone.
Specimen Collection Criteria
Collect: Two plain Red-top tubes.
Do not use Serum Separator Tubes.
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then centrifuge to separate serum from cells within 45 minutes of collection. Transfer serum to a plastic transport tube and freeze (-20°C/-4°F or below) immediately.
Preparation for Courier Transport
Transport: 2.0 mL serum, frozen (-20°C/-4°F or below). (Minimum: 1.0 mL)
Rejection Criteria
- Serum Separator (SST) tubes.
- Specimens not collected and processed as indicated.
In-Lab Processing
Let specimen clot 30-60 minutes then centrifuge to separate serum from cells within 45 minutes of collection. Transfer serum to a plastic transport tube and freeze (-20°C/-4°F or below) immediately.
Transport: 2.0 mL serum, frozen (-20°C/-4°F or below). (Minimum: 1.0 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): unacceptable
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): 28 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Mayo Clinic Laboratories in Rochester, MN.
Performed
Varies.
Results available within 4-7 days.
Reference Range
By report.
Test Methodology
Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).
CPT Codes
82157, 82626, 84403, 84143, 83498
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
11/13/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.