Pre-Transplant Drug Screen (Southeast Michigan Lab Use Only)
Test Codes
EPIC: LAB1231532, Beaker: XPTDS, ARUP: 92420
Department
Send Outs
Instructions
NOTE: This test is only offered to patient’s that are unable to produce urine, i.e., Transplant patients. Urine testing is the preferred source for drug screening, (please see Comprehensive Drug Analysis with Confirmation).
This assay screens for the following drugs:
- Amphetamines
- Barbiturates
- Benzodiazepines
- Buprenorphine / Norbuprenorphine
- Cannabinoids
- Cocaine and Metabolites
|
- Methadone
- Methamphetamines
- Opiates
- Oxycodone
- Phencyclidine
|
Positive screen results are automatically confirmed.
Specimen Collection Criteria
Collect (preferred specimen): Two plain Red-top tubes.
Also acceptable: Three Lavender-top EDTA tubes or three Green-top Sodium Heparin tubes.
Do not use Serum Separator Tubes.
Physician Office/Draw Specimen Preparation
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 4.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 3.0 mL)
Rejection Criteria
- Serum Separator (SST) tubes.
- Specimens not collected and processed as indicated.
In-Lab Processing
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Transport: 4.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 3.0 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 7 days
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): 3 years
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to ARUP Laboratories, Salt Lake City, UT.
Performed
Sunday – Saturday.
Screen results available in 2-4 days.
Confirmation available in 2-5 days.
Reference Range
By report.
Test Methodology
Qualitative Enzyme Linked Immunosorbent Assay/Quantitative Gas Chromatography-Mass Spectrometry/Quantitative Liquid Chromatography-Tandem Mass Spectrometry.
Clinical Utility
Many patients in renal failure cannot produce urine in sufficient amounts to permit a conventional Comprehensive Drug Analysis. An alternative is to perform a screening procedure on serum. Please note that urine provides the greatest opportunity to detect and identify an illicit substance and use of this blood screening procedure for other than Pre-Transplant patients is forbidden. This is a send out test and immediate results are not obtainable. This test is not available on a STAT basis.
CPT Codes
80307; If reflexed (positive), the following may be added: 80324, 80345, 80346, 80348, 80349, 80353, 80358, 80359, 80361, 80365, 83992.
Alternate code: G0479. If reflexed (positive), the following code may be added: G0480.
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
11/13/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.