Moricizine
Ethmozine®
Test Codes
EPIC: LAB6301, Beaker: XMORZ, NMS: 3092
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One plain Red-top tube.
Also acceptable: Two Lavender-top EDTA tubes.
Do not use Serum Separator Tubes.
Time of Collection: Trough, just prior to the next dose.
Physician Office/Draw Specimen Preparation
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 1.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.2 mL)
Rejection Criteria
- Serum Separator (SST) tubes.
- Specimens not collected and processed as indicated.
In-Lab Processing
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Transport: 1.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.2 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 7 days
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): 8 months
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to ARUP Laboratories, Salt Lake City, UT, forwarded to National Medical Services (NMS), Willow Grove, PA.
Performed
Thursday.
Results available in 4-10 days.
Reference Range
By report.
Test Methodology
High Performance Liquid Chromatography / Tandem Mass Spectrometry (LC_MS/MS).
Clinical Utility
Moricizine is indicated for the treatment of documented ventricular arrhythmias, such as sustained ventricular tachycardia, that in the judgement of the physician, are life-threatening. This assay is used for the therapeutic monitoring and toxicity assessment of moricizine.
CPT Codes
80375
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
10/3/2023
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.