Lab Test

Molindone Level, Serum or Plasma

Moban

Test Codes

EPIC: LAB6106, Beaker: XMOLN, NMS: 3082SP

Department

Send Outs

Specimen Collection Criteria

Collect (preferred specimen): One plain Red-top tube.
Also acceptable: Two Lavender-top EDTA tubes.

Do not use Serum Separator Tubes.

Physician Office/Draw Specimen Preparation

Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Preparation for Courier Transport

Transport: 2.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.7 mL)

Rejection Criteria

  • Serum Separator (SST) tubes.
  • Specimens not collected and processed as indicated.

In-Lab Processing

Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Transport: 2.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.7 mL) 

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): 14 days
Refrigerated (2-8°C or 36-46°F): 30 days
Frozen (-20°C/-4°F or below): 30 days

Specimen Storage in Department Prior to Disposal:

Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.

Laboratory

Sent to ARUP Laboratories, Salt Lake City, UT, forwarded to National Medical Services (NMS), Willow Grove, PA.

Performed

Wednesday.
Results available in 4-10 days.

Reference Range

By report.

Test Methodology

High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS).

Clinical Utility

Molindone is a tranquilizer used in the management of psychotic disorders. This assay is used to monitor the therapeutic drug level of Molindone.

CPT Codes

80342

Contacts

Last Updated

10/3/2023

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.