Methsuximide/Normethsuximide
Celontin
Test Codes
EPIC: LAB7145, Beaker: XAMSX, ARUP to NMS: 2950SP
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One plain Red-top tube.
Also acceptable: One Lavender-top EDTA tube.
Do not use Serum Separator Tubes.
Time of Collection: Trough, just prior to the next dose.
Physician Office/Draw Specimen Preparation
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 1.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.3 mL)
Rejection Criteria
- Serum Separator (SST) tubes.
- Specimens not collected or processed as indicated.
In-Lab Processing
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Transport: 1.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.3 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 7 days
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): 18 months
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to ARUP Laboratories, Salt Lake City, UT, forwarded to NMS, Horsham, PA.
Performed
Varies.
Results available within 7 days.
Reference Range
By Report.
Test Methodology
High Performance Liquid Chomatography / Tandem Mass Spectrometry.
Interpretation
By report.
Clinical Utility
Methsuximide is an anticonvulsant indicated for the control of absence (petit mal) seizures that are refractory to other drugs. The methsuximide assay is used to optimize dosage, monitor compliance, and assess toxicity. Normethsuximide is an active metabolite of methsuximide.
CPT Codes
80339, (AH G0480).
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
4/15/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.