Lyme Disease Serology
Lyme Antibody (IgG/IgM), Lyme Ab, Lyme Antibody, IgG/IgM, Lyme Antibody, IgG and IgM
Test Codes
EPIC: LAB1230571, Beaker: LYME
Department
Special Chemistry
Specimen Collection Criteria
Collect: One Gold-top SST tube. (Minimum Whole Blood:
6.0 mL)
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection. (Minimum Serum: 1.5 mL)
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated
(2-8°C or 36-46°F). (Minimum Serum: 1.5 mL)
Rejection Criteria
- Plasma specimens.
- Severely lipemic, icteric, or hemolyzed specimens.
In-Lab Processing
Let specimen clot 30-60 minutes then immediately centrifuge to
separate serum from cells. Room temperature is acceptable for a maximum of two
hours. (Minimum Serum: 1.5 mL)
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 8 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-25°C or 68-77°F): 8 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 8 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 1 year
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Royal Oak Special Testing Laboratory
Performed
Seven days a week.
Results available within 3 business days.
Reference Range
Positive, Negative.
Test Methodology
Multiplex Flow Assay
Interpretation
A negative test result indicates that both IgG and IgM are negative. A positive test result indicates that IgG, IgM, or both are positive. All positive and equivocal results are sent out for Lyme Immunoblot testing. Prompt antibiotic treatment can interfere with specific antibody responses.
Clinical Utility
This assay aids in the diagnosis of infection with B. burgdorferi.
CPT Codes
86618
LOINC: 6320-6
Contacts
Special Chemistry Laboratory – RO
248-551-8071
Name: Special Chemistry Laboratory – RO
Location:
Phone: 248-551-8071
Last Updated
11/4/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.