Lorazepam
Ativan
Test Codes
EPIC: LAB1231327, Beaker: XLORA, Warde: LORAZ
Department
Send Outs
Specimen Collection Criteria
Collect: One plain Red-top tube.
Do not use Serum Separator Tubes.
Time of Collection: Trough, just prior to the next dose.
Physician Office/Draw Specimen Preparation
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 1.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL)
Rejection Criteria
- Serum Separator (SST) tubes.
- Grossly lipemic specimen.
- Grossly hemolyzed specimen.
- Grossly icteric specimen.
- Specimens not collected and processed as indicated.
In-Lab Processing
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Transport: 1.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 48 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 14 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to Warde Medical Laboratory, Ann Arbor, MI.
Performed
Monday, Wednesday, Friday.
Results available in 2-4 days.
Reference Range
Dose-Related Range: 50-240 ng/mL, based on dosages up to 10 mg/d.
Toxic: Greater than 300 ng/mL.
Test Methodology
Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).
Interpretation
By report.
Clinical Utility
Lorazepam is indicated for the management of anxiety disorders or for the short-term relief of the symptoms of anxiety or anxiety associated with depressive symptoms. This assay is used for the therapeutic monitoring and toxicity assessment of lorazepam.
CPT Codes
80346, (Alt G0480).
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
9/17/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.