Immunoglobulin A (IgA), Blood Level
IgA, Immunoglobulin A, Serum
Test Codes
EPIC: LAB73, Beaker: IGA, Antrim: 30425
Department
Chemistry
Specimen Collection Criteria
Collect: One Gold-top SST tube. (Minimum Whole Blood: 4.0 mL)
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within 12 hours of collection. (Minimum Serum: 0.5 mL)
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F). (Minimum Serum: 0.5 mL)
Rejection Criteria
- Grossly lipemic specimens.
- Hemolyzed specimens.
- Plasma specimens.
In-Lab Processing
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of 12 hours. (Minimum Serum: 0.5 mL)
Storage
Specimen Stability for Testing:
Centrifuged SST tubes, Red-top tubes, and Microtainers®
Room Temperature (20-26°C or 68-78.8°F): 12 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 12 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 3 months
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Dearborn Chemistry Laboratory
Royal Oak Automated Chemistry Laboratory
Performed
Sunday – Saturday.
Results available within 24 hours of receipt in the Laboratory.
Reference Range
Current |
Royal Oak and Troy |
0-29 Days: |
8-29 mg/dL |
<1 Year |
0-30 mg/dL. |
1-3 Months: |
8-29 mg/dL |
1-2 Years |
0-90 mg/dL. |
4-6 Months: |
10-47 mg/dL |
3-5 Years |
30-150 mg/dL. |
7-12 Months: |
15-58 mg/dL |
6-13 Years |
50-220 mg/dL. |
13-24 Months: |
20-88 mg/dL |
14-18 Years |
50-209 mg/dL. |
25-36 Months: |
22-78 mg/dL |
Adult |
70-365 mg/dL. |
3-5 Years: |
29-138 mg/dL |
|
|
6-8 Years: |
61-201 mg/dL |
|
|
9-11 Years: |
57-251 mg/dL |
|
|
12-16 Years: |
57-190 mg/dL |
|
|
Adult Range: |
88-374 mg/dL |
|
|
Methodology: Immunoturbidimetric
Test Methodology
Nephelometry.
Interpretation
Decreased IgA levels are associated with selective hypo-IgA, protein-losing enteropathies, hereditary ataxia telangiectasia, and nephrotic syndrome.
Increased IgA levels are associated with infectious diseases, rheumatoid arthritis, polyclonal gammopathies, monocytic leukemia, IgA myeloma, and liver disease.
Half Life in Blood: 6 days.
Clinical Utility
IgA levels are used to evaluate humoral immunity and to aid in the diagnosis of conditions associated with IgA excess or depression. IgA represents 15-20% of the total circulating immunoglobulin pool. It is the predominant immunoglobulin in secretions such as tears, saliva, colostrum, milk, and intestinal secretions.
Clinical Disease
Selective IgA deficiency is a primary immunodeficiency disorder characterized by reduced production of IgA with recurrent respiratory and gastrointestinal infections. Selective IgA deficiency can result from congenital intrauterine infection with rubella virus, Toxoplasma gondii, or cytomegalovirus. A transient IgA deficiency may result following the treatment with penicillamine of Wilson's disease. Most patients with selective IgA deficiencies are asymptomatic. Symptomatic patients usually present with recurrent ear infections, sinusitis, pneumonia, diarrhea, asthma, autoimmune diseases and/or allergies. Administration of blood products containing IgA can cause some IgA deficient patients to develop antibodies against IgA. If an anti-IgA antibody develops, a massive allergic reaction can result during blood or plasma transfusions.
CPT Codes
82784
LOINC: 2458-8
Contacts
Chemistry Laboratory – DBN
313-436-2196
Name: Chemistry Laboratory – DBN
Location:
Phone: 313-436-2196
Automated Chemistry Laboratory – RO
248-551-8065
Name: Automated Chemistry Laboratory – RO
Location:
Phone: 248-551-8065
Last Updated
10/31/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.