House Dust Greer Labs (Allergen Specific IgE)
House Dust (Greer Labs), House Dust, Greer Labs (h1)
Test Codes
Antrim #31385, EPIC: LAB10154, SOFT: EHDG
Department
Immunology
Specimen Collection Criteria
Collect: One Gold-top SST tube.
Twenty individual allergen assays or allergen screens can be performed on one 5 mL Gold-top SST tube. Each allergen assay requires 100 mcL of serum.
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection.
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F).
Rejection Criteria
Plasma specimens.
Severely lipemic or hemolyzed specimens.
In-Lab Processing
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours.
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 1 month
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Royal Oak Special Testing Laboratory
Performed
Monday – Friday.
Results available the next business day.
Reference Range
Allergy Reference Range: Less than 0.35 kU/L.
Range (kU/L) |
Class |
Interpretation |
Less than or equal to 0.34 |
0 |
Negative |
0.35-0.69 |
1 |
Low |
0.70-3.49 |
2 |
Medium |
3.50-17.49 |
3 |
High |
17.50-49.99 |
4 |
Very High |
50.0-100.0 |
5 |
Very High |
Greater than 100 |
6 |
Very High |
Test Methodology
Fluorescence Enzyme Immunoassay (FEIA).
Interpretation
The allergen class may not be predictive of clinical disease in some patients. The diagnosis of allergy should be based upon patient history and clinical findings. The diagnosis of allergy should not be based upon laboratory findings alone.
Clinical Utility
A positive test result (class 1 or greater) is indicative of the presence of allergen-specific IgE and suggests an increased likelihood of allergic disease.
Clinical Disease
House dust is a mixture of potentially allergenic materials including fibers from several types of fabrics, cotton liners, feathers, other stuffing materials, bacteria, mold, fungus spores, food particles, human and pet dander, bits of plants and insects, and pet hair. Intense and lengthy exposure to organic dust may result in developing respiratory symptoms with irreversible physiologic changes. Symptoms that may develop include pulmonary fibrosis, progressive restrictive impairment, diffusion defect, hypoxemia, and a decreased lung function (1). Decreased flow rates, hyperinflation with greatly increased residual volume, decreased diffusing capacity, and a loss of pulmonary elastic recoil pressure (suggesting emphysema) have been found in physiologic studies of affected individuals. Allergic reactions to dust is a progressive disease. Treatment with corticosteroids, bronchodilators, and avoidance of allergen exposure (even for a prolonged time) is only minimally effective (1).
Reference
- Kaplan, Allen P M.D. Allergy. Churchill Livingstone: New York, pg 536, 1985.
CPT Codes
86003
LOINC: 9828-5
Contacts
Special Chemistry Laboratory – RO
248-551-8071
Name: Special Chemistry Laboratory – RO
Location:
Phone: 248-551-8071
Last Updated
7/21/2024