T3 (Triiodothyronine), Free, Blood Level
FT3, Free T3, T3, Free
Test Codes
EPIC: LAB137, Beaker: FRT3
Department
Toxicology
Specimen Collection Criteria
Collect: One Gold-top SST tube. (Minimum Whole Blood: 4.0 mL)
Contact the Laboratory for the acceptability of other tube types.
See Minimum Pediatric Specimen Requirements for Microtainer® collection.
Note: Patient Preparation (Farmington Hills ONLY): Twenty-four (24) hours before this test, the patient should not take multivitamins or dietary supplements containing biotin (vitamin B7) which is commonly found in hair, skin and nail supplements and multivitamins.
Physician Office/Draw Specimen Preparation
Let SST specimens clot for 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged SST tube within two hours of collection. (Minimum: 0.5 mL)
Preparation for Courier Transport
Transport: Centrifuged SST tube, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL)
Rejection Criteria
- Grossly hemolyzed specimens.
- Red-top tubes with serum not separated from cells within two hours of collection.
In-Lab Processing
Let SST specimens clot 30-60 minutes. Centrifuge SST tubes or Microtainers® to separate serum from cells. Deliver immediately to the appropriate testing station.
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-25°C or 68-77°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Royal Oak Automated Chemistry Laboratory
Troy Chemistry Laboratory
Performed
Sunday – Saturday, 24 hours a day.
Results available within 24 hours of receipt in the Chemistry Laboratory.
Reference Range
1.7 - 3.7 pg/mL.
Test Methodology
Chemiluminescence Immunoassay.
Interpretation
Elevated FT3 values are associated with thyrotoxicosis or excess thyroid hormone replacement.
Clinical Utility
Clinically, the FT3 measurement is a second or third level test of thyroid function. It is useful for evaluating the biochemical status of clinically euthyroid patients who have an altered distribution of binding proteins, such as pregnant patients and patients with dysalbuminemia. It also provides a further confirmatory test for hyperthyroidism to supplement the FT4 and sensitive thyrotropin assays. Some investigators recommend the FT3 assay for monitoring thyroid replacement therapy, although its clinical role is not precisely defined.
CPT Codes
84481
Contacts
Automated Chemistry Laboratory – RO
248-551-8065
Name: Automated Chemistry Laboratory – RO
Location:
Phone: 248-551-8065
Chemistry Laboratory – TR
248-964-8070
Name: Chemistry Laboratory – TR
Location:
Phone: 248-964-8070
Last Updated
10/25/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.