Fluphenazine Level
Prolixin, Permitil
Test Codes
EPIC: LAB1231193, Beaker: XFLUP, ARUP: 99906
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One plain Red-top tube.
Also acceptable: One Lavender-top EDTA tube.
Do not use Serum Separator Tubes.
Time of Collection: Pre-dose (Trough), at steady state concentration.
Physician Office/Draw Specimen Preparation
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Preparation for Courier Transport
Transport: 1.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL)
Rejection Criteria
- Serum Separator (SST) tubes.
- Specimens not collected and processed as indicated.
- Hemolyzed specimens.
In-Lab Processing
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).
Transport: 1.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 48 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 30 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to ARUP Laboratories, Salt Lake City, UT.
Performed
Monday, Wednesday, Friday.
Results available in 1-8 days.
Reference Range
Therapeutic Range: 1.0-10.0 ng/mL.
Toxic: Greater than 15 ng/mL.
Test Methodology
Quantitative Liquid Chromatography / Tandem Mass Spectrometry.
Interpretation
By report.
Note: The performance characteristics of this test were validated by ARUP Laboratories, Inc. The U.S. Food and Drug Administration (FDA) has not approved this test. The results are not intended to be used as the sole means for clinical diagnosis or patient management decisions. ARUP is authorized under Clinical Laboratory Improvement Amendments (CLIA) and by all states to perform high-complexity testing.
Clinical Utility
Fluphenazine is a phenothiazine derivative used in the treatment of psychotic disorders. It is also used to alleviate pain and in childhood development disorders. This assay is used for the therapeutic monitoring and toxicity assessment of fluphenazine.
CPT Codes
80342, (alternate code: G0480).
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
7/21/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.