Ethylene Oxide (Allergen Specific IgE)
Ethylene Oxide (k78)
Test Codes
Antrim #31815, LAB1231151, SOFT: EETO
Department
Immunology
Specimen Collection Criteria
Collect: One Gold-top SST tube.
Twenty individual allergen assays or allergen screens can be performed on one 5 mL Gold-top SST tube. Each allergen assay requires 100 mcL of serum.
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection.
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F).
Rejection Criteria
Plasma specimens.
Severely lipemic or hemolyzed specimens.
In-Lab Processing
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours.
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 1 month
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Royal Oak Special Testing Laboratory
Performed
Monday – Friday.
Results available the next business day.
Reference Range
Allergy Reference Range: Less than 0.35 kU/L.
Range (kU/L) |
Class |
Interpretation |
Less than or equal to 0.34 |
0 |
Negative |
0.35-0.69 |
1 |
Low |
0.70-3.49 |
2 |
Medium |
3.50-17.49 |
3 |
High |
17.50-49.99 |
4 |
Very High |
50.0-100.0 |
5 |
Very High |
Greater than 100 |
6 |
Very High |
Test Methodology
Fluorescence Enzyme Immunoassay (FEIA).
Interpretation
The allergen class may not be predictive of clinical disease in some patients. The diagnosis of allergy should be based upon patient history and clinical findings. The diagnosis of allergy should not be based upon laboratory findings alone.
Clinical Utility
A positive test result (class 1 or greater) is indicative of the presence of allergen-specific IgE and suggests an increased likelihood of allergic disease.
Clinical Disease
Ethylene oxide exposure usually occurs as an occupational hazard. Ethylene oxide is used in the production of other compounds such as ethylene glycol (antifreeze), polyesters, and as a sterilant. Health care workers have the greatest risk of exposure to ethylene oxide. Approximately 75,000 health care workers are at increased risk of becoming sensitized to ethylene oxide.
Everyday exposure to ethylene oxide is dangerous not only because of the potential for an allergic reaction but because it is a mutagen, a carcinogen, and a highly reactive substance. Inhalation of the vapors may cause drowsiness, headaches, nausea, breathing difficulties, weakness and diarrhea. Higher concentrations may cause fainting, fluid accumulation in the lungs and even death. Long term exposure to ethylene oxide can cause a skin allergy with the development of a rash and itching.
CPT Codes
86003
LOINC: 6112-7
Contacts
Special Chemistry Laboratory – RO
248-551-8071
Name: Special Chemistry Laboratory – RO
Location:
Phone: 248-551-8071
Last Updated
7/21/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.