Dehydroepiandrosterone (DHEA), Serum
DHEA
    Test Codes
    EPIC: LAB522, Beaker: XDHEAS, MAYO: DHEA
    Department
    Send Outs
    Specimen Collection Criteria
    Collect (preferred specimen): One plain Red-top tube.
Do not use Serum Separator Tubes (SST).
    Physician Office/Draw Specimen Preparation
    Let specimen clot 30-60 minutes then centrifuge to separate serum from cells. Transfer serum to a plastic transport tube and freeze.
    Preparation for Courier Transport
    Transport: 1.0 mL serum, frozen. (Minimum: 0.5 mL)
    Rejection Criteria
    
    - Grossly hemolyzed specimens.
- Grossly lipemic specimens.
- Specimens not collected and processed as indicated.
In-Lab Processing
    Let specimen clot 30-60 minutes then centrifuge to separate serum from cells. Transfer serum to a plastic transport tube and freeze. 
Transport: 1.0 mL serum, frozen. (Minimum: 0.5 mL)
    Storage
    Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): 6 hours
Refrigerated (2-8°C or 36-46°F): 21 days
Frozen (-20°C/-4°F or below): 28 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
    Laboratory
    Sent to Mayo Medical Laboratories, Rochester, MN.
    Performed
    Monday – Thursday.
Results available 2-7 days.
    Reference Range
    By report.
    Test Methodology
    Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).
    Interpretation
    Patients with Cushing's disease may have increased DHEA and increased cortisol levels, and patients with congenital adrenal hyperplasia may have increased DHEA level and decreased cortisol level. However, DHEA currently has not been established for the purpose of differential diagnosis.
Administration of ACTH increases DHEA secretion. Administration of corticosteroids decreases DHEA.
    Clinical Utility
    Elevated plasma DHEA concentrations are suggestive of a heterozygous form of 21-hydroxylase deficiency. Patients with hyperandrogeny of adrenal origin often have an elevated DHEA: androstenedione ratio.
    CPT Codes
    82626
LOINC:  2193-1
    Contacts
    
        
             Send Outs Laboratory – RO 
              
             248-551-9045 
         
        
            Name:  Send Outs Laboratory – RO 
            Location:   
            Phone:  248-551-9045 
         
    Last Updated
    10/22/2024
    Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company. 
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.