Comprehensive Metabolic Panel (CMP)
Comprehensive Metabolic, Panel, CMP, Comp Panel, Comprehensive Metabolic Panel
Test Codes
EPIC: LAB17, Beaker: CMP, Antrim #19051
Department
Toxicology
Instructions
- Blood should be obtained with as little venous stasis (i.e. tourniquet time) as possible. Fist clenching may result in false elevation of potassium and calcium.
- Specimen should be kept tightly closed since CO2 will diffuse out if the tube is uncapped. This will cause an erroneously decreased value.
Specimen Collection Criteria
FOR EC AND INPATIENT SAMPLE COLLECTION ONLY:
Preferred Sample: One Light Green (Mint) Top
Plasma Separator Tube (PST). Minimum Whole Blood: 4.0 mL
Acceptable Sample: One Gold Top SST (Minimum Whole Blood: 4.0 mL)
Do NOT use Dark Green-top Lithium or Sodium Heparin tubes.
FOR PHYSICIAN OFFICE/OUTREACH SAMPLE COLLECTION:
COLLECT: One Gold Top SST (Minimum Whole Blood: 4.0 mL)
Contact Laboratory for acceptability of other tube types. See Minimum Pediatric Specimen Requirements for Microtainer® collection.
Caution: Never refrigerate the collection tube prior to centrifugation. This may cause a falsely elevated potassium.
Physician Office/Draw Specimen Preparation
Let SST specimens clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged SST tube within two hours of collection. (Minimum: 0.5 mL)
Preparation for Courier Transport
Transport: Centrifuged SST tube, refrigerated (2-8°C or 36-46°F). (Minimum: 0.5 mL)
Rejection Criteria
- Moderate to grossly hemolyzed specimens.
- Inadequately centrifuged Microtainers® or Gold-top tubes.
- Red-top tubes with serum not separated from cells within two hours of collection.
In-Lab Processing
Let SST specimens clot 30-60 minutes. Centrifuge SST tubes and Microtainers® to separate serum from cells. Deliver immediately to the appropriate testing station.
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days*
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Canton Chemistry Laboratory
Dearborn Chemistry Laboratory
Farmington Hills Chemistry Laboratory
Grosse Pointe Chemistry Laboratory
Livonia Main Laboratory
Lenox Main Laboratory
Royal Oak Automated Chemistry Laboratory
Troy Chemistry Laboratory
Taylor Chemistry Laboratory
Trenton Chemistry Laboratory
Wayne Chemistry Laboratory
Performed
Sunday – Saturday, 24 hours a day.
Results available within 4 hours.
Reference Range
See specific analytes for reference ranges.
This panel includes: Albumin, Alkaline Phosphatase, (ALP), Alanine Aminotransferase, (ALT), Aspartate Aminotransferase, (AST), Bilirubin, Total, Blood Urea Nitrogen (BUN), Calcium, Carbon Dioxide (CO2), Chloride, Creatinine, Glucose, Potassium, Sodium, and Total Protein.
Test Methodology
Varies.
Interpretation
See specific analytes for interpretation.
This panel includes: Albumin, Alkaline Phosphatase, (ALP), Alanine Aminotransferase, (ALT), Aspartate Aminotransferase, (AST), Bilirubin, Total, Blood Urea Nitrogen (BUN), Calcium, Carbon Dioxide (CO2), Chloride, Creatinine, Glucose, Potassium, Sodium, and Total Protein.
Clinical Utility
This panel is used as a general indicator of metabolic control and to screen for a wide variety of conditions which affect that control.
CPT Codes
80053
Contacts
Livonia Laboratory – LVA
947-523-4370
Name: Livonia Laboratory – LVA
Location:
Phone: 947-523-4370
Lenox Laboratory – LNX
947-523-4070
Name: Lenox Laboratory – LNX
Location:
Phone: 947-523-4070
Chemistry Laboratory – FH
947-521-5252
Name: Chemistry Laboratory – FH
Location:
Phone: 947-521-5252
Chemistry Laboratory – TRN
734-671-3165
Name: Chemistry Laboratory – TRN
Location:
Phone: 734-671-3165
Chemistry Laboratory – DBN
313-436-2196
Name: Chemistry Laboratory – DBN
Location:
Phone: 313-436-2196
Chemistry Laboratory – TYL
313-295-5360
Name: Chemistry Laboratory – TYL
Location:
Phone: 313-295-5360
Main Laboratory –WYN
734-467-4274
Name: Main Laboratory –WYN
Location:
Phone: 734-467-4274
Canton Laboratory – CTN
734-454-8024
Name: Canton Laboratory – CTN
Location:
Phone: 734-454-8024
Automated Chemistry Laboratory – RO
248-551-8065
Name: Automated Chemistry Laboratory – RO
Location:
Phone: 248-551-8065
Chemistry Laboratory – TR
248-964-8070
Name: Chemistry Laboratory – TR
Location:
Phone: 248-964-8070
Chemistry Laboratory – GP
313-473-1807
Name: Chemistry Laboratory – GP
Location:
Phone: 313-473-1807
Last Updated
7/21/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.