Chlorpromazine Level
Thorazine, Ormazine, Largactil
Test Codes
EPIC: LAB1231184, Beaker: XCPL, ARUP #3003036
Department
Send Outs
Specimen Collection Criteria
Collect (preferred specimen): One plain Red-top tube.
Also acceptable: One Lavender-top EDTA tube.
Do not use Serum Separator Tubes.
Time of Collection: Trough, just prior to next dose.
Physician Office/Draw Specimen Preparation
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and freeze (-20°C/-4°F or below).
Preparation for Courier Transport
Transport: 2.0 mL serum or plasma, frozen (-20°C/-4°F or below). (Minimum: 0.5 mL)
Rejection Criteria
- Serum Separator (SST) Tube.
- Whole blood
- Hemolyzed specimens
- Specimens not collected and processed as indicated.
In-Lab Processing
Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and freeze (-20°C/-4°F or below).
Transport: 2.0 mL serum or plasma, frozen (-20°C/-4°F or below). (Minimum: 0.5 mL)
Storage
Specimen Stability for Testing:
Room Temperature (20-26°C or 68-78.8°F): Unacceptable
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): 14 days
Specimen Storage in Department Prior to Disposal:
Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.
Laboratory
Sent to ARUP Laboratories, Salt Lake City, UT.
Performed
Monday.
Results available within 8 days.
Reference Range
See report.
Test Methodology
Quantitative Liquid Chromatography-Tandem Mass Spectrometry.
Interpretation
By report.
Clinical Utility
Chlorpromazine is used to treat psychotic disorders (e.g., schizophrenia), control nausea and vomiting, relieve restlessness prior to surgery, treat acute intermittent porphyria, control the manic phase in bipolar disorders, to treat intractable hiccups, and treat problems in children characterized by hyper-excitable, aggressive stages. This assay is used for the therapeutic monitoring and toxicity assessment of Chlorpromazine.
CPT Codes
80342 (alternate code: G0480).
LOINC: 3471-0
Contacts
Send Outs Laboratory – RO
248-551-9045
Name: Send Outs Laboratory – RO
Location:
Phone: 248-551-9045
Last Updated
7/21/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.