Lab Test

Childhood Panel (IgE)

Childhood Panel IgE

Test Codes

EPIC: LAB1231174, SOFT: ECHLD, Antrim #31999

Department

Immunology

Instructions

This panel includes: Cat DanderCockroachDog DanderEgg WhiteFish (Cod)House Dust Mite (Dermatophagoides farinae)MilkOutdoor Mold (Alternaria Alternata)PeanutSoybeanWheat, and a Total IgE.

Specimen Collection Criteria

Collect: One Gold-top SST tube.

Twenty individual allergen assays or allergen screens can be performed on one 5 mL Gold-top SST tube. Each allergen assay requires 100 mcL of serum.

Physician Office/Draw Specimen Preparation

Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection.

Preparation for Courier Transport

Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F).

Rejection Criteria

  • Plasma specimens.
  • Severely lipemic or hemolyzed specimens.

In-Lab Processing

Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours.

Storage

Specimen Stability for Testing:

Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable

Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-25°C or 68-77°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable

Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 1 month

Specimen Storage in Department Prior to Disposal:

Refrigerated (2-8°C or 36-46°F): 7 days

Laboratory

Royal Oak Special Testing Laboratory

Performed

Monday – Friday.
Results available the next business day.

Reference Range

Allergy Reference Range: Less than 0.35 kU/L.

Range (kU/L) Class Interpretation
≤ 0.34 0 Negative
0.35-0.69 1 Low
0.70-3.49 2 Medium
3.50-17.49 3 High
17.50-49.99 4 Very High
50.0-100.0 5 Very High
> 100 6 Very High

Test Methodology

Fluorescence Enzyme Immunoassay (FEIA).

Interpretation

The allergen class may not be predictive of clinical disease in some patients. The diagnosis of allergy should be based upon patient history and clinical findings. The diagnosis of allergy should not be based upon laboratory findings alone.

Clinical Utility

A positive test result (class 1 or greater) is indicative of the presence of allergen-specific IgE and suggests an increased likelihood of allergic disease.

Reference

  1. American Academy of Allergy, Asthma, and Immunology. Task Force on Allergic Disorders. Executive Summary Report (1998). Available at www.aaaai.org. Accessed October 28, 2004.
  2. Milgrom H, MD, FAAAAI. Understanding allergic Asthma. American Academy of Allergy Asthma, and Immunology. Press release. June 18, 2003.

CPT Codes

82785, 86003x11.

Contacts

Last Updated

10/18/2024

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.