Beta 2 Microglobulin, Serum
Beta-2-Microglobulin, Serum, Beta 2 Microglobulin, Serum
Test Codes
EPIC: LAB1231107, Beaker: B2MG, Antrim: 31360
Department
Toxicology
Specimen Collection Criteria
Collect: One Gold-top SST tube. (Minimum Whole Blood: 2.0 mL)
Physician Office/Draw Specimen Preparation
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection. (Minimum Serum: 0.5 mL)
Preparation for Courier Transport
Transport: Centrifuged collection tube, refrigerated (2-8 °C or 36-46 °F). (Minimum Serum: 0.5 mL)
Rejection Criteria
- Plasma specimens.
- Severely lipemic, icteric, or hemolyzed specimens.
In-Lab Processing
Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours. (Minimum Serum: 0.5 mL)
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gels
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gels
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 14 days
Specimen Storage in Department Prior to Disposal:
Refrigerated (2-8°C or 36-46°F): 7 days
Laboratory
Royal Oak Automated Chemistry
Performed
Monday – Friday.
Results available in 2 business days.
Reference Range
Less than 2.5 mg/L.
Test Methodology
Immunoturbidimetric.
Interpretation
By report.
Clinical Utility
This assay is used to evaluate renal disease and to assess prognosis and monitor lymphoproliferative disorders, such as multiple myeloma and chronic lymphocytic leukemia.
CPT Codes
82232
LOINC: 1952-1, 1953-9
Contacts
Automated Chemistry Laboratory – RO
248-551-8065
Name: Automated Chemistry Laboratory – RO
Location:
Phone: 248-551-8065
Last Updated
7/21/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.