Asparate Aminotransferase (AST)
Test Codes
EPIC: LAB131, AST, Antrim #17264
Department
Chemistry
Specimen Collection Criteria
FOR EC AND INPATIENT SAMPLE COLLECTION ONLY:
Preferred Sample: One Light Green (Mint) Top Plasma Separator Tube (PST). (Minimum Whole Blood: 4.0 mL)
Acceptable Sample: One Gold Top SST (Minimum Whole Blood: 4.0 mL)
Do NOT use Dark Green-top Lithium or Sodium Heparin tubes.
FOR PHYSICIAN OFFICE/OUTREACH SAMPLE COLLECTION:
COLLECT: One Gold Top SST (Minimum Whole Blood: 4.0 mL)
Contact Laboratory for acceptability of other tube types.
See Minimum Pediatric Specimen Requirements for Microtainer® collection.
Physician Office/Draw Specimen Preparation
Let SST specimens clot 30–60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2–8°C or 36–46°F) the centrifuged SST tube within two hours of collection. (Minimum: 0.5 mL)
Preparation for Courier Transport
Transport: Centrifuged SST tube, refrigerated (2–8°C or 36–46°F). (Minimum: 0.5 mL)
Rejection Criteria
Moderate to grossly hemolyzed specimens (due to in vitro hemolysis).
Red-top tubes with serum not separated from cells within two hours of collection.
In-Lab Processing
Let SST specimens clot 30-60 minutes. Centrifuge SST tubes and Microtainers® to separate serum from cells. Deliver immediately to the appropriate testing station.
Storage
Specimen Stability for Testing:
Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20–26°C or 68–78.8°F): 2–4 hours
Refrigerated (2–8°C or 36–46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable
Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20–26°C or 68–78.8°F): 2–4 hours
Refrigerated (2–8°C or 36–46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable
Serum Specimens (Pour-Overs)
Room Temperature (20–26°C or 68–78.8°F): 2–4 hours
Refrigerated (2–8°C or 36–46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days
Specimen Storage in Department Prior to Disposal:
Refrigerated (2–8°C or 36–46°F): 7 days
Laboratory
Canton Chemistry Laboratory
Dearborn Chemistry Laboratory
Farmington Hills Chemistry Laboratory
Grosse Pointe Chemistry Laboratory
Livonia Main Laboratory
Lenox Main Laboratory
Royal Oak Automated Chemistry Laboratory
Troy Chemistry Laboratory
Taylor Chemistry Laboratory
Trenton Chemistry Laboratory
Wayne Chemistry Laboratory
Performed
Sunday – Saturday, 24 hours a day.
STAT results available within 1 hour of receipt in the Laboratory.
Routine results available within 4 hours.
Reference Range
<35 U/L.
Test Methodology
Enzymatic.
Interpretation
Elevated AST occurs with hepatocyte damage (rather than obstructive liver disease) including viral toxic hepatitis, cirrhosis, hepatic congestion and fatty liver. A normal AST does not exclude cirrhosis. An aspartate aminotransferase to alanine aminotransferase (AST/ALT) ratio of greater than 2 suggests alcoholic hepatitis rather than viral hepatitis. Increased AST levels also occur following myocardial infarction, skeletal muscle disease and hemolysis (in vivo or in vitro).
Clinical Utility
The quantitative determination of AST (aspartate aminotransferase) aids in the diagnosis and management of certain types of liver disease. AST is no longer recommended for diagnosis of myocardial infarction.
CPT Codes
84450, 1920-8
Contacts
Canton Laboratory – CTN
734-454-8024
Name: Canton Laboratory – CTN
Location:
Phone: 734-454-8024
Chemistry Laboratory – DBN
313-436-2196
Name: Chemistry Laboratory – DBN
Location:
Phone: 313-436-2196
Chemistry Laboratory – FH
947-521-5252
Name: Chemistry Laboratory – FH
Location:
Phone: 947-521-5252
Chemistry Laboratory – GP
313-473-1807
Name: Chemistry Laboratory – GP
Location:
Phone: 313-473-1807
Lenox Laboratory – LNX
947-523-4070
Name: Lenox Laboratory – LNX
Location:
Phone: 947-523-4070
Livonia Laboratory – LVA
947-523-4370
Name: Livonia Laboratory – LVA
Location:
Phone: 947-523-4370
Automated Chemistry Laboratory – RO
248-551-8065
Name: Automated Chemistry Laboratory – RO
Location:
Phone: 248-551-8065
Chemistry Laboratory – TYL
313-295-5360
Name: Chemistry Laboratory – TYL
Location:
Phone: 313-295-5360
Chemistry Laboratory – TRN
734-671-3165
Name: Chemistry Laboratory – TRN
Location:
Phone: 734-671-3165
Chemistry Laboratory – TR
248-964-8070
Name: Chemistry Laboratory – TR
Location:
Phone: 248-964-8070
Main Laboratory –WYN
734-467-4274
Name: Main Laboratory –WYN
Location:
Phone: 734-467-4274
Last Updated
10/16/2024
Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.