Lab Test

NMR LipoFit Profile

NMR Lipo Profile

Test Codes

EPIC: LAB6800, Beaker: XNMR1, ARUP: 2013716

Department

Send Outs

Instructions

Fast 12 hours prior to specimen collection.

Specimen Collection Criteria

Collect (preferred specimen): One Greiner Bio-One Clot Activator Tube.
Also acceptable: Two plain Red-top tube.

Serum specimens drawn in any other gel barrier collection tube will be rejected, due to interfering substances that make them unacceptable for NMR analysis.

 

Physician Office/Draw Specimen Preparation

Let specimen clot for 30 minutes then centrifuge to separate serum from cells within 8 hours of collection. Transfer serum to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Preparation for Courier Transport

Transport: 4.0 mL serum, refrigerated (2-8°C or 36-46°F). (Minimum 2 mL)

Rejection Criteria

  • Serum Separator (SST) tubes.
  • Plasma.
  • Specimens not collected and processed as indicated.

In-Lab Processing

Let specimen clot for 30 minutes then centrifuge to separate serum from cells within 8 hours of collection. Transfer serum to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Transport: 4.0 mL serum, refrigerated (2-8°C or 36-46°F). (Minimum 2.0 mL)

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): 24 hours
Refrigerated (2-8°C or 36-46°F): 14 days
Frozen (-20°C/-4°F or below): Unacceptable

Specimen Storage in Department Prior to Disposal:

Specimen retention time is determined by the policy of the reference laboratory. Contact the Send Outs Laboratory with any questions.

Laboratory

Sent to ARUP Laboratory in Salt Lake City, UT.

Performed

Sunday – Saturday.
Results available in 3-6 days.

Reference Range

By report.

Test Methodology

Quantitative Nuclear Magnetic Resonance (NMR) Spectroscopy / Quantitative Enzymatic / Detergent Solublization.

Interpretation

By report.

Clinical Utility

Use in appropriate high-risk patients (e.g., type 2 diabetes mellitus) in whom LDL particle number is being used to guide therapy. Not recommended for cardiovascular disease risk assessment in most individuals.

CPT Codes

80061, 83704.

Contacts

Last Updated

10/8/2023

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.