800-551-0488

Lab results are too important to go anywhere else

Beaumont Laboratory

Vitamin B12

VB12, B12, EPIC: LAB5130, SOFT: VB12

Specimen Collection Criteria

Collect: One Gold-top SST tube. (Minimum Whole Blood: 4.0 mL)
Contact Laboratory for acceptability of other tube types.

It is recommended that specimen be protected from light.

Physician Office/Drawsite Specimen Preparation

It is recommended that specimen be protected from light. Let SST specimens clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged SST tube within two hours of collection. (Min: 0.5 mL)

Preparation for Courier Transport

Transport: Centrifuged SST tube, refrigerated (2-8°C or 36-46°F). (Min: 0.5 mL)

Rejection Criteria

  • Moderate to grossly hemolyzed specimens.

Storage

Specimen Stability for Testing:

Centrifuged SST tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable

Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable

Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2-4 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 7 days

Specimen Storage in Department Prior to Disposal:

Refrigerated (2-8°C or 36-46°F): 7 days

Laboratory

Farmington Hills Chemistry Laboratory.
Grosse Pointe Chemistry Laboratory.
Royal Oak Automated Chemistry Laboratory.
Troy Chemistry Laboratory.

Performed

Sunday - Saturday, 24 hours a day. 
Results available within 24 hours after receipt in the Laboratory.

Reference Range

Adult range: 271 - 870 pg/mL.

Deficient: Less than 200 pg/mL.
Borderline: 200 - 270 pg/mL.
Normal: 271 - 870 pg/mL.
High: Greater than 870 pg/mL.

Test Methodology

Chemiluminescence Immunoassay.

Interpretation

A decreased serum Vitamin B12 level may occur in a number of disorders, most of which are due to malabsortion of Vitamin B12 from the small intestine. The most common of these is pernicious anemia in which intrinsic factor production is reduced; this will also occur following total gastrectomy. Disease or resection of the terminal small intestine prevents absorption of Vitamin B12. Although rare, disorders of transcobalamins, can lead to decreased serum Vitamin B12.

Excessive exposure to light may alter Vitamin B12 values.

Clinical Utility

Vitamin B12 deficiency is usually due to malabsorption resulting from: deficiency of intrinsic factor, disease or resection of the terminal small bowel, or utilization of the vitamin by excessive bacterial flora in the gut. It may also occur in strict vegetarians where insufficient Vitamin B12 is present in the diet.

Vitamin B12 deficiency can result in: macrocytic anemia, neuropathy, psychiatric changes, mental impairment (dementia), and infertility.

Since macrocytic anemia often requires measurement of both Vitamin B12 and folate levels it may be more economical and convenient to perform both tests at the same time.

CPT Code

82607.

Test Codes

EPIC: LAB5130, SOFT: VB12

Last Updated

12/29/2017

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.

This directory currently reflects information only for specimens collected and/or processed at the Farmington Hills, Grosse Pointe, Royal Oak, and Troy campuses.