Lab Test

Honey Bee Venom (Allergen Specific IgE)

Honey Bee Venom (i1)

Test Codes

Antrim #31860, EPIC: LAB5650, SOFT: EHB

Department

Special Testing Allergens

Specimen Collection Criteria

Collect: One Gold-top SST tube.

Twenty individual allergen assays or allergen screens can be performed on one 5 mL Gold-top SST tube. Each allergen assay requires 100 mcL of serum.

Physician Office/Draw Specimen Preparation

Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Refrigerate (2-8°C or 36-46°F) the centrifuged collection tube within two hours of collection.

Preparation for Courier Transport

Transport: Centrifuged collection tube, refrigerated (2-8°C or 36-46°F).

Rejection Criteria

Plasma specimens.

Severely lipemic or hemolyzed specimens.

In-Lab Processing

Let specimen clot 30-60 minutes then immediately centrifuge to separate serum from cells. Room temperature is acceptable for a maximum of two hours.

Storage

Specimen Stability for Testing:

Centrifuged SST Tubes and Microtainers® with Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): Unacceptable

Red-top Tubes and Microtainers® without Separator Gel
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): Unacceptable
Frozen (-20°C/-4°F or below): Unacceptable

Serum Specimens (Pour-Overs)
Room Temperature (20-26°C or 68-78.8°F): 2 hours
Refrigerated (2-8°C or 36-46°F): 7 days
Frozen (-20°C/-4°F or below): 1 month

Specimen Storage in Department Prior to Disposal:

Refrigerated (2-8°C or 36-46°F): 7 days

Laboratory

Royal Oak Special Testing Laboratory

Performed

Monday – Friday.
Results available the next business day.

Reference Range

Allergy Reference Range: Less than 0.35 kU/L. 

Range (kU/L) Class Interpretation
Less than or equal to 0.34 0 Negative
0.35-0.69 1 Low
0.70-3.49 2 Medium
3.50-17.49 3 High
17.50-49.99 4 Very High
50.0-100.0 5 Very High
Greater than 100 6 Very High

Test Methodology

Fluorescence Enzyme Immunoassay (FEIA).

Interpretation

The allergen class may not be predictive of clinical disease in some patients. The diagnosis of allergy should be based upon patient history and clinical findings. The diagnosis of allergy should not be based upon laboratory findings alone.

Clinical Utility

A positive test result (class 1 or greater) is indicative of the presence of allergen-specific IgE and suggests an increased likelihood of allergic disease.

Clinical Disease

In the United States it is estimated that one to two million people are severely allergic to stinging insect venoms. Approximately 90 to 100 deaths occur annually from sting reactions. This number may under-represent the true total because some sting reactions are misdiagnosed as heart attacks, sunstrokes, or other acute illnesses. Death can occur without a previous history of a sting allergy. The frequency of fatal reactions due to anaphylaxis increases with age.

Prophylactic measures must be taken for those individuals who develop severe reactions to insect stings. Specific immunotherapy (hyposensitization) remains the most effective means of treatment with a 96% success rate (1).

Reference

  1. Kaplan, Allen P. M.D. Allergy. Churchill Livingstone: New York, pg. 508-509, 1985.

CPT Codes

86003
LOINC: 6843-7