800-551-0488

Lab results are too important to go anywhere else

Beaumont Laboratory

Trihexyphenidyl

Artane®, ARUP #91399, EPIC: LAB6169, SOFT: XTHPL

Specimen Collection Criteria

Collect (preferred specimen): Two plain Red-top tubes.
Also acceptable: Two Lavender-top EDTA tubes.

Do not use Serum Separator Tubes.

Time of Collection: Trough, just prior to the next dose.

Physician Office/Drawsite Specimen Preparation

Centrifuge to separate serum or plasma from cells. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Preparation for Courier Transport

Transport: 4.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Min: 2.2 mL)

Rejection Criteria

  • Serum Separator (SST) tubes.
  • Specimens not collected and processed as indicated.

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): 7 days
Refrigerated (2-8°C or 36-46°F): 14  days
Frozen (-20°C/-4°F or below): 1 year

Specimen Storage in Department Prior to Disposal:

Specimen retention time is determined by the policy of the reference laboratory. Contact the Sendout Laboratory with any questions.

Laboratory

Sent to ARUP Laboratories, Salt Lake City, UT, forwarded to National Medical Services (NMS), Willow Grove, PA.

Performed

Varies.
Results available in 4-11 days.

Reference Range

By report.

Test Methodology

Quantitative Gas Chromatography.

CPT Code

80375 (alternate code: G0480).

Test Codes

ARUP #91399, EPIC: LAB6169, SOFT: XTHPL

Last Updated

08/30/2017

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.

This directory currently reflects information only for specimens collected and/or processed at the Farmington Hills, Grosse Pointe, Royal Oak, and Troy campuses.