800-551-0488

Lab results are too important to go anywhere else

Beaumont Laboratory

Trifluoperazine

Stelazine®, NMS #4660SP, Order as a Miscellaneous Sendout.

Specimen Collection Criteria

Collect (preferred specimen): Two plain Red-top tubes.
Also acceptable: Two Lavender-top EDTA tubes.

Do not use Serum Separator Tubes.

Time of Collection: Trough, just prior to the next dose.

Physician Office/Drawsite Specimen Preparation

Centrifuge to separate serum or plasma from cells within two hours of collection. Transfer serum or plasma to a plastic transport tube and refrigerate (2-8°C or 36-46°F).

Preparation for Courier Transport

Transport: 2.0 mL serum or plasma, refrigerated (2-8°C or 36-46°F). (Min: 0.7 mL)

Rejection Criteria

  • Serum Separator (SST) tubes.
  • Specimens not collected and processed as indicated.

Storage

Specimen Stability for Testing:

Room Temperature (20-26°C or 68-78.8°F): 24 hours
Refrigerated (2-8°C or 36-46°F): 30 days
Frozen (-20°C/-4°F or below): 24 months

Specimen Storage in Department Prior to Disposal:

Specimen retention time is determined by the policy of the reference laboratory. Contact the Sendout Laboratory with any questions.

Laboratory

Sent to ARUP Laboratories, Salt Lake City, UT, forwarded to National Medical Services (NMS), Willow Grove, PA.

Performed

Varies.
Results available in 4-11 days.

Reference Range

By report.

Test Methodology

High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS).

CPT Code

80342.

Test Codes

NMS #4660SP, Order as a Miscellaneous Sendout.