800-551-0488

Lab results are too important to go anywhere else

Beaumont Laboratory

Specimen Collection Manual: Cerebrospinal Fluid (CSF) Specimen Collection, Labeling, and Transport

CSF, Cerebral Spinal Fluid, CSF Specimen Collection and Labeling, Cerebrospinal Fluid (CSF) Specimen Collection and Labeling

Instructions

  • Materials Needed: CSF Collection Kit.
  • CSF is normally clear and colorless. Xanthochromia is a term used to describe CSF supernatant that has a pink, yellow, or orange color. Xanthochromia is reported by the Hematology Laboratory as part of the Cell Count procedure.
  • The protocol for proper CSF collection requires that an aliquot of CSF be placed in sequentially numbered and properly labeled sterile tubes as the fluid is collected. Specimens are usually collected in four sterile tubes, which are labeled 1, 2, 3, and 4 in the order in which they are withdrawn.

Specimen Collection Criteria

The CSF tubes/containers, included in the CSF kit, have numbers 1-4 etched near the top of the container. The tube labeled 1 is collected first. Each tube hold a maximum of 8.0 mL.

Tube # Test Name Volume Required
Tube 1 CSF Protein, Glucose 1.0-2.0 mL
Tube 1 CSF Oligoclonal Banding (includes IgG)* 1.5 mL
Tube 1 CSF Myelin Basic Protein 1.0 mL
Tube 2 Microbiology/Serology Studies** See below
Tube 3 CSF Cell Count 1.0 mL
Tube 3 CSF Flow Cytometry for Lymphoproliferative Disorder 1.0 mL
Tube 4 Cytology Studies 1.0 mL
Tube 4 Hold 1.0 mL

*Blood (one Gold-top SST tube) is also required.

**Microbiology/Serology Requirements
Lab Section: Microbiology
Tube # Test Name Volume Required
Tube 2 CSF Routine Bacterial Culture 1.0 mL
Tube 2 Fungal Culture 2.0 mL
Tube 2 CSF Viral Culture*** 2.0 mL
Tube 2 CSF Mycobacterial Culture 5.0 - 7.0 mL
Tube 2 Bacterial Antigen Detection 0.5 mL
Tube 2 Cryptococcal Antigen 0.5 mL
Lab Section: Special Testing
Tube 2 CSF Arbovirus IgM Panel 2.0 mL
Tube 2 CSF HSV, VZV, and/or Enterovirus PCR 1.0 mL
Tube 2 CSF Syphilis VDRL 0.5 mL

***There is no need to use viral transport media with CSF as it usually contains enough protein for protection of any viruses that might be present.

Rejection Criteria

  • Expired media is not acceptable. Check the expiration date on all media prior to specimen collection.

Last Updated

04/14/2014

Microtainer® and Vacutainer® are registered trademarks of Becton, Dickinson and Company.
UroVysion® is a registered trademark of Abbott Laboratories. ThinPrep® is a registered trademark of Hologic, Incorporated.

This directory currently reflects information only for specimens collected and/or processed at the Farmington Hills, Grosse Pointe, Royal Oak, and Troy campuses.